BECKETT 7556A0000U GENISYS 12VDC PRIMARY CONTROL
Specifications
| Return Shipping Will Be Paid By | Buyer |
| All Returns Accepted | Returns Accepted |
| Item Must Be Returned Within | 30 Days |
| Refund Will Be Given As | Money Back |
| Brand | Beckett |
Beckett 7556A0000U GeniSys 7556A 12VDC Oil Burner Control Electrical RatingsInputs- Voltage: 12 Vdc nominal (11 to 16 Vdc)- Current: 160 mA plus burner motor, igniter, and valve loadsOutputs- Motor: 12 Vdc, 20 full load amps (FLA), 100 locked rotor amps (LRA)- Igniter: 12 Vdc, 5 A- Solenoid Valve: 12 Vdc, 2 A- Lockout Alarm: 12 Vdc, 2 AEnvironmental Ratings- Storage & Operating Ambient Temperature: -40°F to +160°F (-40°C to +71°C)- Moisture: 5 to 95% RH, condensingLockout Time 15 SecThe Beckett GeniSy 12 V Advanced Burner Control is a 12 VDC primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors, to name a few examples. The GeniSys 12 V is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time. Beckett 7556A0000U GeniSys 7556A 12VDC Oil Burner Control 15 Second Lockout